You've got a desktop, a monitor, maybe a small NAS. The national chain says "six to eight business days." Your deadline is tonight. The BK650-AS puts 35 minutes of clean power behind your critical gear at 100 W – enough to save, close, and power down properly before the lights go. Three outlets are battery-backed; one is surge-only for the peripheral that doesn't need the full ride. It's a tower unit, not rack-mountable, so it lives on your desk or in the corner of the room. The lead-acid battery is user-replaceable (RBC17, compatible with BATT17-1209) – when it's time, you swap it yourself. No waiting for a technician. 45 dBA. 230 V input, IEC C14 in, three IEC C13 battery outlets plus one surge C13. The RJ45 phone/fax/DSL line protector is included. Straightforward protection for a single workstation or a small home-office setup that's been running on bare mains too long
| brand | APC |
| model | BK650-AS |
| series | Back-UPS |
| rated_power_va | 650 VA |
| rated_power_w | 400 W |
| ups_type | Standby |
| wave_type | Stepped approximation to a sinewave |
| input_voltage | 230 V |
| output_voltage | 230 V |
| input_connection | IEC 60320 C14 |
| output_connections | 3× IEC 60320 C13, 1× IEC 60320 C13 surge |
| total_outlets | 4 |
| battery_type | Lead-acid (user-replaceable) |
| replacement_battery | RBC17 |
| compatible_batteries | BATT17-1209 |
| runtime_100w | 35 min |
| cable_length_m | 1.83 |
| acoustic_level_dba | 45 |
| mounting | Tower (not rack-mountable) |
| data_line_protection | RJ45 analog phone / fax / DSL |
| operating_temp_c | 0–40 |
| storage_temp_c | -15–45 |
| network_frequency_hz | 50/60 ± 3 (auto-sensing) |
| category | Electronics & Components > Power & Batteries |